处理中...

Thinking...

AI is analyzing your product

60s

Refrigerant Mixture (For Air Conditioning)

CN → US
HS编码 关税税率 原产国 目的国 文档
2903490000 13.7% CN US 官方文档
3827690000 38.7% CN US 官方文档
3824995500 38.7% CN US 官方文档
3827390000 38.7% CN US 官方文档

商品图片

AI分析

🌡️ Refrigerant Mixture (For Air Conditioning)


🌐 HS Code Classification & Customs Clearance Guide | 2026 Latest Tariff Analysis | Strategic Compliance Strategy
📌 I. Product Definition: What is a "Refrigerant Mixture"?

Refrigerant mixtures for air conditioning are complex chemical compositions designed to transfer heat in HVAC systems. They are rarely single elements but rather blends of halogenated hydrocarbons, specifically derivatives of methane, ethane, or propane.

In international trade, these products are strictly regulated due to environmental concerns (ozone depletion and global warming potential). The classification depends heavily on the specific chemical structure and the presence of halogens (fluorine, chlorine, bromine, etc.).

⚠️ Critical Distinction:
- Saturated Fluorinated Non-Cyclic Hydrocarbon Derivatives (HFCs without chlorine) often fall under specific chemical derivative headings.
- Halocarbon Mixtures or mixtures containing specific halogenated derivatives often fall under "Prepared" chemical products or other hydrocarbon derivatives.
- Chlorine-containing compounds (HCFCs/HFCs with Cl) are treated differently than pure Fluorinated ones.


📦 II. HS Code Classification Details (Based on Provided Data)

HS Code Product Description & Summary Key Chemical Characteristics
2903.49.00.00 Refrigerant Mixture: Halogenated hydrocarbon derivative. Fits the definition of saturated fluorinated non-cyclic hydrocarbon derivatives. Pure HFC blends; No chlorine; Saturated structure.
3827.69.00.00 Refrigerant Mixture: Contains halogenated derivatives of methane, ethane, or propane. Classified under Other Hydrofluorocarbons (HFCs). Specific HFC blends containing methane/ethane/propane derivatives.
3824.99.55.00 Refrigerant Mixture: Halogenated hydrocarbon mixture. Inferential classification under the Residual/Catch-all category for halogenated mixtures. Complex mixtures not fitting specific chemical headings; "Other" prepared chemicals.
3827.39.00.00 Refrigerant Mixture: Halogenated hydrocarbon mixture. Fits characteristics of Chlorofluorocarbons (CFCs), Hydrochlorofluorocarbons (HCFCs), and related derivatives. Contains Chlorine (Cl) alongside Fluorine (F); Older generation refrigerants.

🔍 Classification Logic:
- If the mixture is a pure HFC (Hydrofluorocarbon) without chlorine, it may lean toward 2903.49.00.00 or 3827.69.00.00 depending on specific derivative rules.
- If the mixture contains Chlorine (HCFC/CFC blends), it falls under 3827.39.00.00.
- If the chemical structure is too complex or "prepared" for a specific chemical heading, it defaults to the residual category 3824.99.55.00.


💰 III. 2026 Latest Tariff Rate Breakdown (Including Surcharges & Policy Add-ons)

Applicable Country: USA (US)
Country of Origin: China (CN)
Effective Date: Current regime applies (Section 301 + IEEPA)

🎯 1. 2903.49.00.00 — Saturated Fluorinated Non-Cyclic Hydrocarbon Derivatives

Item Detail
Base Tariff 3.7% (General Rate)
Section 301 Surcharge 0.0%
122 Section / IEEPA Surcharge 10%
Total Effective Rate 13.7%
Tax Calculation CIF Value × 13.7%
De Minimis Exemption Not Eligible (High-risk chemical product)
Legal Authority Path IEEPA:9903.01.24USITC:2903.49.00.00Section 122 Tariff

📌 Explanation:
- This is the most favorable classification among the four options.
- It enjoys a 0% Section 301 surcharge, likely due to specific exclusions or lower strategic sensitivity compared to other HFC categories.
- The 10% IEEPA tariff still applies to Chinese-origin goods.


🎯 2. 3827.69.00.00 — Other Hydrofluorocarbons (HFCs)

Item Detail
Base Tariff 3.7%
Section 301 Surcharge 25.0%
122 Section / IEEPA Surcharge 10%
Total Effective Rate 38.7%
Tax Calculation CIF Value × 38.7%
De Minimis Exemption Not Eligible
Legal Authority Path IEEPA:9903.01.25Section 301USITC:3827.69.00.00

📌 Explanation:
- Subject to the full 25% Section 301 tariff due to its classification under specific HFC headings.
- High cost implication for importers.


🎯 3. 3824.99.55.00 — Other Prepared Chemicals (Halogenated Mixtures)

Item Detail
Base Tariff 3.7%
Section 301 Surcharge 25.0%
122 Section / IEEPA Surcharge 10%
Total Effective Rate 38.7%
Tax Calculation CIF Value × 38.7%
De Minimis Exemption Not Eligible
Legal Authority Path IEEPA:9903.01.25Section 301USITC:3824.99.55.00

📌 Explanation:
- Falls into the "Catch-all" category for prepared chemicals.
- Treated similarly to 3827.69.00.00 with high surcharges.


🎯 4. 3827.39.00.00 — Chlorofluorocarbons & Derivatives

Item Detail
Base Tariff 3.7%
Section 301 Surcharge 25.0%
122 Section / IEEPA Surcharge 10%
Total Effective Rate 38.7%
Tax Calculation CIF Value × 38.7%
De Minimis Exemption Not Eligible
Legal Authority Path IEEPA:9903.01.25Section 301USITC:3827.39.00.00

📌 Explanation:
- Chlorine-containing refrigerants are heavily regulated environmentally and tariffs reflect this.
- High risk of environmental compliance checks.


🛠️ IV. Customs Clearance Practical Advice (Avoid Pitfalls)

✅ 1. Essential Documentation Checklist (Non-Negotiable)

Document Requirement Description
Safety Data Sheet (SDS) Mandatory Must comply with OSHA GHS standards. Clearly list all chemical components and percentages.
Ingredient Declaration Mandatory Exact chemical names, CAS numbers, and proportions. Vague terms like "HFC blend" will lead to delays.
EPA Certificate Conditional If the product contains regulated substances, EPA Section 608 compliance may be required for HVAC use.
Commercial Invoice Mandatory Must specify "Refrigerant Mixture," HS Code, and Country of Origin clearly.
Packing List Mandatory Detail weight, volume, and container type (e.g., steel cylinders, gas cylinders).
MSDS/SDS for Customs Mandatory Specifically for hazardous materials classification.

✅ 2. Declaration Strategy (Key Tips)

🔥 “Chemical Specificity is Key!”

Scenario Correct Declaration Wrong Practice Consequence
Pure HFC Mix Explicitly state "Saturated Fluorinated Non-Cyclic Hydrocarbon Derivative" Generic "Refrigerant" Misclassification → 13.7% vs 38.7% risk
HCFC/CFC Mix State "Chlorofluorocarbon Mixture" Omit chlorine content Environmental violation → Seizure
Complex Blend Use "Halogenated Hydrocarbon Mixture" Guessing HS Code Duty underpayment → Penalties
Cylinders Declare as "Charged Cylinders" Declare as "Empty Cylinders" Hazardous material surcharge if not declared

✅ 3. Special Circumstances Handling

Situation Recommendation
OEM/Private Label Provide manufacturer’s chemical analysis report to prove composition for accurate HS coding.
Small Sample Shipments Even small quantities are subject to the same high tariffs; De Minimis does not apply.
Used/Recycled Refrigerant May require additional EPA permits and different HS codes; consult EPA guidelines.
Non-Chinese Origin If sourced from Vietnam, Mexico, or India, Section 301 and IEEPA tariffs may be reduced/eliminated. Verify Origin Certificate.

🌍 V. Global Market Comparison (2026)

Region Recommended HS Code Tariff Impact Notes
🇺🇸 USA 2903.49.00.00 (Best Case) 13.7% (Best) Highest duty if misclassified to 3827 or 3824.
🇨🇳 China 3827 or 2903 Varies Export duties may apply; check Chinese export regulations.
🇪🇺 EU 3824 or 2903 Varies F-Gas Regulation applies; quota limits for HFCs.
🇬🇧 UK 3824 or 2903 Varies Post-Brexit rules apply; F-Gas similar to EU.

📌 Conclusion:
- USA is the most tariff-sensitive market due to Section 301 and IEEPA.
- Classifying under 2903.49.00.00 saves ~25% in duties compared to other categories.
- Origin matters: Sourcing from non-China countries can significantly reduce total landed cost.


📌 VI. Common Errors & Pitfalls (Lessons Learned)

Error 1: Declaring "Refrigerant" without chemical specifics
👉 Result: Customs issues a "Request for Information" (RFI), delaying shipment by weeks.

Error 2: Misclassifying HFCs as "Prepared Chemicals" (3824) when they fit 2903
👉 Result: Paying 38.7% instead of 13.7%. Overpayment!

Error 3: Ignoring EPA Regulations
👉 Result: Cargo held at port for EPA compliance review. Fines up to $10,000 per day.

Error 4: Assuming "De Minimis" applies to small refrigerant cans
👉 Result: Seizure of goods. Chemical products are explicitly excluded from $800 de minimis exemption.

Correct Approach:

“Hydrofluorocarbon Refrigerant Mixture, Composition: R-410A (50% HFC-32 / 50% HFC-125), SDS Provided, EPA Compliant, Model XYZ”


🎯 VII. Conclusion: Precise Classification Saves Money!

🎯 Remember:

🔹 “HS Code Dictates Duty: 13.7% vs 38.7% – a 25% Gap!”
🔹 “No De Minimis for Chemicals – Every Penny is Taxable!”
🔹 “Origin is King – Non-China Source = Tariff Avoidance!”


📌 Pro Tip:
If your refrigerant is sourced from Vietnam, Mexico, or India, apply for a Certificate of Origin to potentially bypass Section 301 and IEEPA tariffs.
Consider Advance Rulings from CBP to secure the 13.7% rate for 2903.49.00.00 if chemically eligible.


📣 Immediate Action:

📞 Engage a licensed customs broker.
📄 Provide full SDS and ingredient list.
🚀 Optimize supply chain for lowest duty liability.


Professional Clearance Starts with Accurate Classification!
💼 Your Profit Margin Depends on Your HS Code Choice!

用户评价

关于 HS 编码归类

协调制度(HS)是由世界海关组织(WCO)制定的国际贸易商品分类标准。全球 200 多个国家采用 HS 系统作为海关关税、贸易统计和进出口监管的基础。

每个 HS 编码遵循以下层级结构:

  • 章(2 位)——商品大类(例如:第 84 章:机器和机械设备)
  • 品目(4 位)——章内的更具体分类
  • 子目(6 位)——国际通用细分,所有 WCO 成员国统一使用
  • 本国细分(8-10 位)——各国自行扩展的细分编码,如美国 HTSUS 10 位编码

正确的 HS 编码归类对于顺利通关、准确缴纳关税和遵守贸易法规至关重要。错误归类可能导致海关延误、多缴关税或罚款。

CN进口到US时,适用的关税税率可能包括:

  • 最惠国(MFN)税率——适用于 WTO 成员国的标准关税税率
  • 普通税率——适用于无贸易协定国家
  • 贸易救济关税——附加关税,如 301 条款(反倾销)、232 条款(国家安全)或反补贴税

本页内容仅供参考。如需正式归类,请咨询当地海关或持牌报关代理。